A typical FDRINC Volume Incremental Backup system consists of:
  • Full-volume backups (usually taken once per week) where all data on a volume is backed up.

  • Incremental backups (usually taken once per day) where only the changed data sets are backed up.


The backups created by FDRINC are fully “managed”, which means they are recorded and tracked by an automated recording mechanism. From those managed backups, either the whole volume or individual data sets can be easily restored.
  • Restoring individual data sets...The most recent copy of a data set can be restored by specifying just the data set name. Additional options are available to allow older copies of the data set to be restored, if required.

  • Recreating entire DASD volumes...If one or more volumes have been lost, perhaps due to hardware problems or as a consequence of a disaster, these volumes can be automatically recovered from a combination of their full and incremental backups...


Backup Example – “Full Volume” Backup

//BACKUP    EXEC  PGM=FDRABR,REGION=0M
//TAPE1      DD   UNIT=3590-1,DSN=FDR1,DISP=(,KEEP),VOL=(,,,255)
//TAPE2      DD   UNIT=3590-1,DSN=FDR2,DISP=(,KEEP),VOL=(,,,255)
//TAPE3      DD   UNIT=3590-1,DSN=FDR3,DISP=(,KEEP),VOL=(,,,255)
//SYSIN      DD   *

    DUMP TYPE=FDR,ONLINE,DSNENQ=USE,RTC=YES
    EXCLUDE ALLDSN,VOLG=WORK


Some points to note about the above example job:
  • The DUMP TYPE=FDR statement instructs ABR to take a full-volume dump of the selected volumes.

  • The combination of the ONLINE parameter (on the DUMP statement) and the subsequent EXCLUDE statement instructs ABR to select all DASD volumes that are online to the z/OS system, with the exception of the WORK volumes.

  • Three TAPEx DD statements have been provided so that three disk volumes will be concurrently dumped.

  • As each tape drive becomes available at the end of backing up a DASD volume, ABR will automatically piggyback the next disk volume as the next file on that tape.

  • The DSNENQ=USE parameter causes ABR to issue an informational message for any dataset that was OPEN at the time of the backup. These datasets will still be backed up.

  • RTC=YES will significantly reduce the back elapsed time by using READ TRACK CCWs to read disk data tracks.

  • After the backup of each volume is completed and recorded, the MVS Update Bits will be turned off for all datasets on the volume.
Using the simple job above, with a single control statement, you could backup a large number of DASD volumes.

Restore Example – Volume Recovery

If disk failures occur, or if a DASD volume has to be restored at a disaster site, FDRINC automates the volume restore process by locating the most recent set of full-volume and incremental backups.

It starts off the restore process by reading the most recently-created incremental, restoring the label track, VTOC, VTOCIX, VVDS and any datasets on that backup. It then reads back through the preceding incrementals and the full-volume backup, restoring the most recent copy of each dataset—once only.

The result of this restore process is a volume that looks exactly like the original volume at the time of the last backup, whether it was a full-volume or an incremental backup. All the datasets are in their original locations, with the exact same allocation characteristics.

The following example job shows the JCL and control statements required to recover a disk volume called PROD01 from the full-volume and incremental backups. Notice how only the volser of PROD01 has been specified.

The DYNTAPE parameter tells FDRINC to identify from its control files the backup tapes that are required to complete the restore.

The DISK1 DD points to the output volume that will be used for the restore (SPARE1) and the CPYVOLID=YES tells FDRINC to rename SPARE1 to PROD01 after the contents of PROD01 have been restored to it.

//RESTFULL    EXEC  PGM=FDRABR,REGION=0M
//SYSPRINT     DD   SYSOUT=*
//SYSUDUMP     DD   SYSOUT=*
//DISK1        DD   UNIT=3390,VOL=SER=SPARE1,DISP=OLD
//SYSIN        DD   *

    RESTORE TYPE=FDR,CPYVOLID=YES,DYNTAPE
    SELECT VOL=PROD01,NVOL=SPARE1