Innovation has discovered a problem that can cause VSAM data sets with certain unusual
characteristics to be corrupted when they are restored, copied, or moved to a cylinder
number higher than 32767. Although this is only possible when the output volume is a
3390-54, we urge all customers to apply the following ZAP as soon as possible. Please do not
delay installing the ZAP because you have not installed any 3390-54's yet, because you may not
remember when you do install them.
If you do have 3390-54 volumes and you suspect that you have been affected by this problem,
please contact Innovation for instructions on identifying and repairing affected data sets.
***** ZAP-ID# : P-54.6067
* PREREQ : V 5.4/60 OR 61
* STATUS : APPLIED V 5.4/62;
* CORRESPONDING ZAP FOR 5.4/50-53 IS P-54.5107;
* CORRESPONDING ZAP FOR 5.4/55-56 IS P-54.5613
* SYMPTOMS : FDRDSF,FDRCOPY,FDRABR:FDRDSFC:INCORROUT. AFTER
* A RESTORE, COPY, OR MOVE OF A VSAM DATA SET TO A
* 3390-54 WHERE THE DATA SET GOT ALLOCATED ABOVE
* CYLINDER 32767, THE HI-A-RBA AND THE HIGH-RBA
* VALUES IN THE VVR TYPE 23 CELL MAY BE SET
* INCORRECTLY. THIS PROBLEM MAY CAUSE FDRCPK TO
* GET AN ABEND S0C9 AND/OR TO ISSUE ERROR MESSAGE
* CPK583E REASON=E.
* SOLUTION : APPLY ZAP.
* NOTE : FDRPAS/FDRMOVE DOES NOT HAVE THIS PROBLEM.
*-
NAME FDRDSFC FDRDSFC
IDRDATA P546067
VER 0106 D106,D108
VER 8866 4B10,E002
VER C57A 4B00,E002
REP 0106 4B10,E002,5410,98EC,07FF,4B00,E002,5400
REP 0116 98EC,47F0,B5C2
REP 8866 45F0,D106
REP C57A 47F0,D110
CHECKSUM 3424C88A
*
* THE FOLLOWING ZAP IS FOR FDRCPK CUSTOMERS ONLY
*
*-
NAME FDRRESTR FDRRESTR
IDRDATA P546067
VER 1D40 BD40,BD42
VER 21AC 92C5,DB27
REP 1D40 92C5,DB27,5500,A97C,4780,A1B8,07F1
REP 21AC 4510,BD40
CHECKSUM 8FD13659
*
***** END OF MODIFICATION
If you are running an older release than V 5.4/60, then you can download the corresponding fix from the Innovation FTP site at: http://www.innovationdp.fdr.com/ftp/ftp.cfm
For V 5.4/50 through V 5.4/53: file /download/FDR_V54/P545107.txt
For V 5.4/55 through V 5.4/56: file /download/FDR_V54/P545613.txt
If you have not already registered for FTP access, click on the "Register for FTP Site Access" link.
If you are already registered, enter your access code (use capitals for any letters in your access code) and click on the "FTP Login" link.
NEW FEATURES AVAILABLE IN FDR V5.4 L62
Version 5.4 L62 is now available.
New features:
FDRINSTANT now supports space efficient (SE) FlashCopy.
FDRINSTANT now supports incremental FlashCopy.
The documentation for these features is in the ICL library, in member FC5462.
Any version of FDR is compatible with dynamic volume expansion. After you expand a volume size using dynamic
volume expansion and run the ICKDSF REFORMAT command to rebuild the VTOC and VTOC index, the FDR system will
recognize the new volume size.
LATEST PRODUCT RELEASE INFORMATION
Please review the link below for product information, and particularly the updates for FDR when archiving
in a z/OS 1.8 system and for the new PDSE feature of buffering beyond CLOSE in z/OS 1.6 and above.